Edit Template

CyStain™ BacCount Kits

  • CyStain™ BacCount Kit – Complete Microbiological Monitoring of Wastewater | Waste Water
Small white plastic bottle and several plastic tubes with different colored caps and liquids
CyStain BacCount Viable Kit

CyStain™ BacCount Kits

Microbiological control of your wastewater, always in view

Monitor, optimize, and design your wastewater treatment processes more efficiently with the Sysmex Partec CyStain™ BacCount Kits by quickly, sensitively, and automatically determining the total number of bacteria and their vitality in the wastewater.

LoD | Cells/ml
< 0
Detection time
< 0 min
Tests/Kit
0

Applications

  • Our system supports microbiological quality control in various areas of water management:

    • Wastewater treatment plants – Monitoring biological cleaning processes, detecting microbial contamination, and ensuring stable effluent values.
    • Water treatment – Control of process and purified water for microbiological parameters, prevention of contamination, and quality assurance in accordance with the Drinking Water Ordinance.
  • Ideal for:

    • Operators of municipal and industrial wastewater treatment plants
    • Laboratories for environmental and water analysis
    • Engineering offices and plant constructors in the field of water technology
    • Operators of waterworks and treatment plants
    • Research institutions focusing on environmental and process microbiology

Advantages at a glance

  • Rapid quantification of bacteria in less than 20 minutes
  • Counts all bacterial cells (CyStain™ BacCount Total), including non-culturable cells (VBNC – Viable But Not Culturable), and differentiates between viable and non-viable cells (CyStain™ BacCount Viable)
  • Enables rapid and clear assessment of the microbiological status
  • Automatic, objective data analysis and generation of analysis reports
  • Optimized for routine analysis in industrial applications
  • Low detection limit

Our Solutions - Your Safety

CyStain™ BacCount - For routine quality control of wastewater samples – so you can keep a complete overview of your microbiological parameters at all times.

Wastewater goes through a variety of processes to be safely returned to the environment. A crucial process step is monitoring the total bacterial count at various points in the treatment. The CyStain™ BacCount Kits support you in this by providing rapid and cost-effective quantification of all bacteria and their differentiation into viable and non-viable bacteria. This includes not only the culturable but also non-culturable bacteria (Viable But Not Culturable – VBNC). Thus, the CyStain™ BacCount Kits provide you with an overall picture of the microbiological status and enable you to optimally monitor, improve, and design your processes more efficiently.

Do you have questions or technical problems?
Our experts have the answers.

We provide precise, rapid and reliable microbiological quality control for demanding applications.

Contact
Initial consultation
Edit Template
Edit Template

Technical details / specifications

Technology & Analysis Times

Feature Description
Technology Cell staining with DNA dyes and flow cytometric analysis
Time-to-result with manual measurement < 20 minutes
Analysis time for automatic measurement < 40 minutes (96 samples with CyFlow™ AL-20 Autoloader)
Technology Cell staining with DNA dyes and flow cytometric analysis
Time-to-result with manual measurement < 20 minutes
Analysis time for automatic measurement < 40 minutes (96 samples with CyFlow™ AL-20 Autoloader)

Detection Limits & Test Number

Feature Description
Detection limit 200 cells/ml total bacterial count VBNC with CyStain™ BacCount Total
Detection limit 500 cells/ml VBNC with CyStain™ BacCount Viable
Number of tests/kit 200 for manual measurement in test tubes;
1000 for automatic measurement with the Autoloader AL-20 in microtiter plates
Detection limit 200 cells/ml total bacterial count VBNC with CyStain™ BacCount Total
Detection limit 500 cells/ml VBNC with CyStain™ BacCount Viable
Number of tests/kit 200 for manual measurement in test tubes;
1000 for automatic measurement with the Autoloader AL-20 in microtiter plates

#SPGsolutions

Typical challenges

Steel pipes in a plant with water in the foreground

All information at a click

Here you will find all the important documents, media and technical details about the product – clearly arranged, up-to-date and immediately available.

Why you will love this product
Fast Smart Reliable Simply good.

Fast. Smart. Reliable. Simply good.
Our solution impresses with lightning-fast application, intuitive operation and razor-sharp results.
Whether in everyday laboratory work or in quality control, this kit delivers what it promises: speed, precision and security.

With our innovative flow cytometry solutions, we enable precise, fast, and reliable tests for microbiological quality control and process optimization – in the beverage, food, cosmetics, water, paper, and ploidy industries.

Opening Hours:

Monday – Friday: 8:00 AM – 4:00 PM
Saturday & Sunday: Closed

Newsletter

Sign up for our newsletter now and receive exclusive insights, the latest news, and valuable tips directly in your inbox!

You have successfully subscribed! Oops! Something went wrong, please try again.

Contact

Purchasing / Purchase

Sales / Sales

© 2025 by Sysmex Partec GmbH
and Richter Consults – Digital Excellence & Strategy for IT, Marketing and more for transformative business solutions.

Legal Notice . Privacy Policy